Complete Pre-Engineered Fire Detection & Suppression Systems
MAE Series complete pre-engineered fire detection & suppression systems are A-C or A-B-C Rated using 3M™ Novec™ 1230 Fire Protection Fluid.
FIREBOY MAE Series Fire Detection & Suppression System Advantages
Land based clean agent applications such as server rooms and laboratories up 1,800 cubic feet (with 3M™ Novec™ 1230)
Pre-engineered System
All Components Included in the Kit
Fast Installation with One Technician
Competitively Priced Total Installed Cost
No Engineering or Piping Calculations Required
Perfect for use in:
- Server Rooms
- Laboratories
- Computer Rooms
- Control Rooms
- Records & Data Centers
- Media Storage
- Reference Material
- Clean Rooms
- Grow Rooms & Labs
- Telecommunication Centers
- Flammable Liquid Storage
- Robotic Equipment
- Textile Manufacturing
- Electric Utility Facilities
- Testing / Image Equipment
- Military Applications
- Historical Collections
- Other Enclosed Spaces
The Fireboy MAE System is Pre-Engineered And FM Approved
The MAE System is a complete pre-engineered, FM approved, Fire Detection and A-C or A-B-C Suppression system using 3MTM NovecTM 1230 Fire Protection Fluid and a patent pending electric release including:
- Two (2) Smoke Detectors, Photo-Electric
- One (1) Pull Station
- One (1) Fire Bell
- Two (2) Horn/Strobes
- Release Panel Available in Red or Gray Finish
- One (1) Abort Switch
- One (1) Disablement Switch
- Pre-engineered MAE Suppression System (155°F/68°C) with 3MTM NovecTM 1230 Fire Protection Fluid
- One (1) Extinguisher Circuit Test Module
- Two (2) Caution / Warning Signs
- Unique Safety Pin Supervision System
- Power Supply and Safety Pin are Supervised by the Release Panel
- Quick Connect Electrical Connectors
- Easy Installation
Fireboy MAE System Application Parameters:
- Single Extinguisher System Up to 1,800 cu. ft.
- Maximum Ceiling Height is 11.3 ft.
- Maximum Reach is 21.0 ft.
- Locate Extinguisher Nozzle Within 24 in. of Ceiling
Release Panel
- Large LED Display
- UL864 and FM Approved
- Supervision of Power Supply and “Proofing Pin”
- Configurable First Stage NAC Delays
- Configurable Detection Delays
- Configurable Releasing Delays Up to 60 Seconds in 5 Second Steps
- Configurable Releasing Duration Up to 5 Minutes in 5 Second Steps
- Available in Red or Gray Finish
- 115/1/60 or 230/1/50 or 60 Supply Voltage
Customize With System Options and Additional Components
MAE Pre-Engineered System Options
- Extra Smoke Detectors, Photo-Electric
- Heat Detectors, 135˚F/57°C
- Call Point in Lieu of Pull Station
- Pull Cable
- 135°F/57°C or 175°F/80°C Operation
Expand Your System With Additional Components
- Extra Smoke Detectors
- Extra Pull Stations or Call Points
- Extra Horn/Strobes
- Extra Fire Bells