Fire Detection System Types
Commercial
USCG Approved
Elite RSM Series
Analog Addressable
2 Loop
Our VES Series feature an addressable USCG Approved Systems.
The monitor control panel has two loops and is designed to accommodate 126 smoke and/or heat detectors per loop.
Battery back-up maintains system monitoring even when 24 VDC power is not available.
Repeater Panels are available for installation in key monitoring regions.
Recreational
Yachts
FR Series
Non-Addressable
1, 2, 4, 8, 16 Zones
The Fireboy-Xintex Fire Detection Products offer many desirable features and functions in marine fire detection equipment.
Our FR Series were designed with the yacht and cabin cruiser customer in mind.
Our sleek, compact design in the FR-1000 and FR-2000 Models are encased in 2-5/8″ square front bezel.
Up to 14 smoke and/or heat detectors (12DC system) may be connected to each zone. Designed for use with the Apollo Series 65 UL Listed detectors.
Commercial IMO/ Solas Approved
Syncro ASM Series
Analog Addressable
2 Loop
The Syncro ASM Series meet international standards, IMO / Solas, RINA, BV, GL. Conforms to FSS Code Ch 9.
This is an addressable series with 2 loops capable of 126 smoke or heat detectors per loop.
Designed for use with Apollo Discovery Detectors.
Battery back-up maintains the monitoring even when 240V AC Power is not available.
Repeater Panels are available for installation into key monitoring regions.